Customization: | Available |
---|---|
Output Type: | Single Phase |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | FLRS-35-24 | FLRS-75-24 | FLRS-150-24 | |
Output | Direct Voltage | 24V | ||
Rated Current | 1.5A | 3.2A | 6.5A | |
Current Range | 0 ~ 1 .5A | 0 ~ 3 .2A | 0-6.5A | |
Rated Power | 36W | 76.8W | 156W | |
Ripple and Noise (Max) | 150mVp-p | 200mVp-p | ||
Voltage Adjustment Range | 21.6 ~ 28 .8V | |||
Voltage Accuracy | ±1 .0% | |||
Line Regulation | ±0 .5% | |||
Load Regulation | ±0 .5% | |||
Startup, Rise Time | 1000ms , 30ms/230VAC 2000ms ,30ms/115VAC at full load | 500ms , 30ms/230VAC 500ms ,30ms/115VAC (full load) | ||
Hold-up Time (Typ.) | 30ms/230VAC 12ms/115VAC at full load | 60ms/230VAC 12ms/115VAC(full load) | 40ms/230VAC 35ms/115VAC (full load) | |
Input | Voltage Range | 85 ~ 264VAC /120 ~ 373VDC | 85 ~ 132VAC /170 ~ 264VAC( selected by switch ) 240 ~ 370VDC(switch on 230VAC) | |
Frequency Range | 47 ~ 63Hz | |||
Efficiency (Typ.) | 88% | 90% | 89% | |
AC Current (Typ.) | 0.7A/115VAC 0.42A/230VAC | 1.4A/115VAC 0.85A/230VAC | 2.8A/115VAC 1.6A/230VAC | |
Surge Current (Typ.) | Cold Start 45A/230VAC | Cold Start 65A/230VAC | ||
Leakage Current | <0 .75mA / 240VAC |
Protection | Overload | 110 ~ 150% of Rated Output Power | Rated output power 110-140% | |
Protection Mode: Hiccup Mode, automatically recovers after abnormal condition is removed | ||||
Overvoltage | 28.8 ~ 33 .6V | |||
Protection Mode: Shut Down Output Voltage, auto-recovery after restart | ||||
Environment | Operating Temperature | '-30 ~ +70°C (please refer to "Derating Curve") | ||
Operating Humidity | 20-90% RH, non-condensing | |||
Storage Temperature, Humidity | '-40 ~ +85℃, 10 ~ 95% RH, | |||
Temperature Coefficient | ±0 .03%/℃ (0 ~ 50℃) | |||
Vibration Resistance | 10 ~ 500Hz, 5G 10 minutes/period, X, Y, Z each 60 minutes |